EXTRACTED TEXT FROM: Instructions for PHILIPS 300W Beam Light.docx

Beam shaking lamp
Use to explain the book.


Please read the instructions carefully before use.
Please read the instructions carefully before use.

Catalogue
1.Precautions and installation 1
1.1Declaration 1
1.2Maintenance 1
1.3Product precautions 1
1.4Product Instructions 1
1.5 Connecting signal cables 2
1.6Lighting installation 2
 2.Control panel 4
2.1 Key instructions
2.2.1Setting 5
2.2.2Manual 5
2.2.3Information 6
2.2.4Factory 7
3.Channel function 8
3.1Channel table 8
4.Common faults 11

1. Precautions and Installation Precautions and Installation
statement
Thank you for choosing our products! This product has good performance and complete packaging when it leaves the factory. For your safe and effective use of this product, please read this instruction manual carefully and completely before you use this product. This manual contains important information about installation and use. Please install and operate according to the requirements of the manual. At the same time, please keep this manual properly for use at any time. Our company is not responsible for any damage to lamps or other performance due to personal failure to follow the instructions during installation, use and maintenance.
This manual is subject to technical changes without prior notice.

maintaining
Please disconnect the power supply before carrying out maintenance.
This lamp should be kept dry to avoid working in wet environment.
Intermittent use will effectively prolong the life of this lamp.
In order to obtain good ventilation effect and lighting effect, attention should be paid to cleaning fans, fan nets and lenses frequently.
Please don't use alcohol and other organic solvents to wipe the lamp shell to avoid damage.

Precautions for products
This lamp is for professional use only.
Before operation, ensure that the power supply voltage is consistent with the power supply voltage required by the equipment.
Do not place this product in a place that is easy to loosen or vibrate.
During use, if the lamps are abnormal, stop using them in time.
In order to ensure the service life of the product, this product should not be placed in a damp or leaking place, and it should not work in an environment where the temperature exceeds 60 degrees.
When the light bulb is used, the change of power supply voltage should not exceed 10%. If the voltage is too high, the life of the light bulb will be shortened, and if the voltage is too low, the light color of the light bulb will be affected.
After the power is cut off, it takes 20 minutes to fully cool the lamps before they can be powered on again.
The rotating parts and pasted fittings of lamps and lanterns must be inspected regularly, and they should be reinforced in time to prevent accidents.
To ensure the normal use of this product, please read this instruction carefully.

Product introduction
Total power: w;
Voltage: AC100V-240V 50/60Hz.
Color wheel: each color wheel consists of 13 color plates+white light;
Pattern disk: 14 pattern effects;
540 translation, 270 tilt.
Overheating protection;
Control mode: voice control, self-propelled, master-slave and DMX512.
IP20 protection level

Signal wire connection
Lamps and lanterns are equipped with standard DMX input and output 3-core or 5-core XLR sockets. Please use twisted-pair signal wire specially shielded for DMX 512; Generally, the connection distance of signal lines is 150 meters. When transmitting long-distance signals, DMX512 signal amplifier must be added.
Use a shielded twisted-pair signal line to connect from the DMX output port of the controller to the DMX input port of the first device, and from the DMX output port of the first device to the DMX input port of the second device, and so on until all the lamps are connected, and then install a terminal plug on the last 3-core jack connected to the lamp output of each connection. (Weld a 4/1W, 120Ω resistor between pins 2 and 3 of the 3-core Canon plug with needle).

Important: The wires must not touch each other or the metal shell.


Fig. 1 schematic diagram of DMX signal line connection
Calculation method of initial address code of lamps and lanterns:
The starting address code of the current lamp is equal to (the starting address code of the previous lamp)+(the number of channels of the lamp).
1: The initial address code value A001 of the first lamp.
2. The number of basic channels of the controller should be greater than or equal to the total number of channels used by lamps.
3. Note: When using any controller, each lamp must have its own starting address code. If the starting address code of the first lamp is set to A001, the number of lamps is 16CH; Then the starting address code of the second lamp is set to A017; The starting address code of the third lamp is set to A033; And so on, (this setting mode also needs to be determined according to different consoles)

Lighting installation
Lamps and lanterns can be placed horizontally, hung obliquely and upside down. Pay attention to the installation method when hanging obliquely and upside down.
such asfigure 1As shown in the figure, before positioning the lamps, it is necessary to ensure the stability of the installation site. During the reverse hanging installation, it is necessary to ensure that the lamps do not fall off the support frame, and it is necessary to use a safety rope to pass through the support frame and the lamp handle for auxiliary hanging to ensure safety and prevent the lamps from falling and sliding.
When installing and debugging lamps, pedestrians are forbidden to pass below, and regularly check whether the safety rope is worn and the hook screw is loose.
If the hanging installation is unstable and the lamps fall, our company will not bear any responsibility.

pictureoneSchematic diagram of upside-down lamps
















control panel

2.1 key description





Fig. 3 schematic diagram of panel key explanation
Let's take "Modify DMX Address Code" as an example to describe the use of keys:
1. If it is not the main interface at present, press the "Left" key (one or more times) to return to the main interface.
2. In the main interface, press the "Up" key or the "Down" key to select the "Settings" button.
3. Press the "OK" key to enter the "Settings" interface.
4. In the Settings interface, press the Up key or the Down key to select DMX Address.
5. Press the "OK" key to enter the editing state.
6. Press the "Up" or "Down" key to modify the DMX address code.
7. Press "OK" to exit the editing status.







2.2 menu description

2.2.1 menu display
Menu display
primary menu
Submenu 1
Function setting
Brief introduction of function
DMX address

1-512

system setup
Display backward
normal
.


turn


Language settings
Chinese



English


Channel mode
20CH


operational mode
DMX



sound-controlled



automatic


Electronic lighting
close



open


Bulb default
On _ off


Bulb control
illumine


shortest route
On _ off


Horizontal reversal
close



open


Vertical inversion
close



open


XY speed
low speed



intermediate speed



fast


Optocoupler detection
close



open


Return to the superior
▲

information inquiry
Total time
0-9999


Bulb time
0-9999


binding hours
0-9999


display software
Vx001


XY software
Vx001


Small motor software
Vx001


Return to the superior
▲

Channel control
Color wheel rotation
0-255


stroboscopic
0-255


Dimming "
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


Fogging
0-255


Focus adjustment
0-255


Horizontal rotation
0-255


Horizontal fine adjustment
0-255


Vertical rotation
0-255


Vertical fine tuning
0-255


reset
0-255


light a lamp
0-255


XY speed
0-255


Color wheel speed
0-255


Focusing speed
0-255


Pattern speed
0-255


Return to the superior
0-255

functional mode
XY communication
normal
current state


mistake


Small motor communication
normal



mistake


Focusing hall
normal



mistake


Color wheel hall
normal



mistake


Pattern hall
normal



mistake


X-optical coupler
normal



mistake


Y optocoupler
normal



mistake


Fan speed
6500


Return to the superior
▲

appurtenance
Check code 1
0-9999


Total time
clear



carry out


Lamp time
clear



carry out


Restore default
default



recover



preserve


Horizontal rotation
0-255
Zero initial position

Vertical rotation
0-255


Focus adjustment
0-255


Prism 1
0-255


Prism 2
0-255


Prism rotation 1
0-255


Prism rotation 2
0-255


Fogging
0-255


Color combination
0-255


Fixed pattern
0-255


colour disc
0-255


Frequency flash
0-255


Stroboscopic midpoint
0-255


Ridge-1 midpoint
0-255


Mid-point of edge two
0-255


Atomization midpoint
0-255


Colorful midpoint
0-255


Return to the superior
▲

Advanced settings
Check code 2
0-9999


Signal encryption
open



close


DMX speed
0-255


DMX data packet
0-255


DMX type
0-055


DMX isolation
0-65535
The smaller the value, the more stable the signal is.

Driving plate temperature
< 110 degrees >
If it exceeds this range, red will be displayed.

Drive board 3.3V
3.0V - 3.6V
If it exceeds this range, red will be displayed.

Drive board 5.0V
4.5V - 5.5V
If it exceeds this range, red will be displayed.

Drive board 12V
10.0V - 14.0V
If it exceeds this range, red will be displayed.

Drive plate 36V
20.0V - 42.0V
If it exceeds this range, red will be displayed.

X state
be motionless



turn


X hall
normal



mistake
Show red

X-ray optical coupler phase
0-3


X optocoupler a
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler b
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler c
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler d
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X current angle
000-540


X drive state
normal



mistake
Show red

Y state
be motionless



turn


Y optocoupler
normal



mistake
Show red

Y hall
normal



mistake
Show red

Y-coupler phase
0-3


Y optocoupler a
40-160
If it exceeds this range, red will be displayed.

Y optocoupler b
40-160
If it exceeds this range, red will be displayed.

Y optocoupler c
40-160
If it exceeds this range, red will be displayed.

Y optocoupler d
40-160
If it exceeds this range, red will be displayed.

Y current angle
000-250


Y drive state
normal



mistake
Show red

Return to the superior
▲

Channel level
Color wheel rotation
0-255
Current DMX channel value

stroboscopic
0-255


aiming
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


Fogging
0-255


Focus adjustment
0-255


Horizontal rotation
0-255


Horizontal fine adjustment
0-255


Vertical rotation
0-255


Vertical fine tuning
0-255


reset
0-255


light a lamp
0-288


XY speed
0-255


Color wheel speed
0-255


Focusing speed
0-255


Pattern speed
0-255


Return to the superior


reset
Reset all
cancel
manual reset


carry out


XY reset
cancel



carry out


Effect reset "
cancel



carry out


Return to the superior


Exit menu




Channel function
3.1 channel table
passage
16-channel mode
one
Color wheel
2
Cut light/strobe
three
aiming
four
Pattern disk
five
Prism 1
six
Prism rotation
seven
Prism 2
eight
atomize
nine
focus
10
X
11
X fine tuning
twelve
Y
13
Y fine tuning
14
XY speed
15
various colours
16
Light bulb & reset



Channel parameter value (full version):
passage
function
Channel value
effect
one
Color wheel
000 - 004
005 - 009
010 - 014
015 - 019
020 - 024
025 - 029
030 - 034
035 - 039
040 - 044
045 - 049
050 - 054
055 - 059
060 - 064
065 - 069
070 - 074
075 - 079
080 - 084
085 - 089
090 - 094
095 - 099
100 - 104
105 - 109
110 - 114
115 - 119
120 - 124
125 - 129
130 - 134
135 - 139
140 - 144
145 - 149
150 - 203
204 - 255
white light
White light+color 1
Color 1
Color 1+ Color 2
Color 2
Color 2+ color 3
Color 3
Color 3+ color 4
Color 4
Color 4+ color 5
Color 5
Color 5+ color 6
Color 6
Color 6+ color 7
Color 7
Color 7+ color 8
Color 8
Color 8+ color 9
Color 9
Color 9+ color 10
Color 10
Color 10+ color 11
Color 11
Color 11+ color 12
Color 12
Color 12+ color 13
Color 13
Color 13+ color 14
Color 14
Color 14+ white light
Reverse flow (from fast to slow)
Forward flow (from slow to fast)
2
stroboscopic
000-007
008-015
016-131
132-167
168-203
204-247
248-255
Shutter closed
Shutter open → (controlled by dimming channel)
Strobe from slow to fast
Slow on fast off strobe from slow to fast.
Turn on and off the strobe from slow to fast.
Random strobe from slow to fast
Shutter open → (controlled by dimming channel)
three
aiming
000-255
From dark to bright
four
Pattern disk
000 - 004
005 - 009
010 - 014
015 - 019
020 - 024
025 - 029
030 - 034
035 - 039
040 - 044
045 - 049
050 - 054
055 - 059
060 - 064
065 - 069
070
071 - 075
076 - 080
081 - 085
086 - 090
091 - 095
096 - 100
101 - 105
106 - 110
111 - 115
116 - 120
121 - 125
126 - 130
131 - 135
136 - 139
140 - 189
190 - 194
195 - 255
Baiguangkong
Solid figure 1
Solid figure 2
Solid figure 3
Solid figure 4
Solid figure 5
Solid figure 6
Solid figure 7
Solid figure 8
Solid figure 9
Solid figure 10
Solid figure 11
Solid figure 12
Solid figure 13
Baiguangkong
Figure 1 jitter (from slow to fast)
Figure 2 jitter (from slow to fast)
Figure 3 jitter (from slow to fast)
Figure 4 jitter (from slow to fast)
Figure 5 jitter (from slow to fast)
Figure 6 jitter (from slow to fast)
Figure 7 jitter (from slow to fast)
Figure 8 jitter (from slow to fast)
Figure 9 jitter (from slow to fast)
Figure 10 jitter (from slow to fast)
Figure 11 jitter (from slow to fast)
Figure 12 jitter (from slow to fast)
Figure 13 jitter (from slow to fast)
Baiguangkong
Forward flow (from fast to slow)
Baiguangkong
Reverse flow (from slow to fast)
five
Prism 1
000-015
016-255
Prism 1 pops up.
Prism 1 cuts in
six
Prism 1 rotates
000-127
128-187
188-195
196-255
stop
Reverse rotation (from fast to slow)
stop
Forward rotation (from slow to fast)
seven
Prism 2
000-015
016-255
Prism 1 pops up.
Prism 1 cuts in
eight
atomize
000-015
016-255
without
Atomization cut-in
nine
focus
000-255
Pattern clarity from far to near
10
X axis
000-255
Horizontal 540-degree scanning
11
X-axis fine tuning
000-255
Horizontal 1.2-degree fine adjustment
twelve
Y axis
000-255
Vertical 270-degree scanning
13
Y axis fine tuning
000-255
Vertical 1.2-degree fine adjustment
14
XY speed
000-255
Speed from fast to slow
15
various colours
000-127
128-255
without
Colorful cut-in
16
Light bulb & reset
000-099
100-105
200-205
250-255
No, there is no action in the area where the function is not specified.
Extinguish the light bulb
Light the bulb
All motors reset


Common faults
Aiming at some common faults, the corresponding solutions are put forward. Any problem that cannot be solved should be handled by professionals. Please disconnect the power supply before maintaining the lamps.
The light bulb doesn't work
Check whether the voltage matched with the lamp is installed;
Check whether the power supply connection or control switch of lamps and lanterns is in poor contact;
Check whether the power supply is insufficient;
Check whether the DMX512 controller has sent instructions.

Lamps and lanterns do not accept the control of the console after normal reset.
Check whether the digital starting address value and function options of lamps and lanterns are correct;
Check whether the connection of the communication control line is correct, the communication line is too long or has been interrupted;
Check whether the control equipment fails, and check whether the signal amplifier connected in series fails;
Check whether the communication line is too long or other equipment interferes with each other;
Optimize wiring, shorten the length of control signal line, and separate wiring for high voltage and low voltage lines;
Add a signal amplifier;
The signal line adopts high-quality shielded twisted pair;
Connect the signal termination resistor (120 ohms) at the end of the lamp.

Lamps can't start.
Check whether the parameters of power supply are consistent with the lamps;
Check the lamps for poor contact due to extrusion deformation, vibration and humidity of internal parts during long-distance transportation.
Or fall off.
Please check whether the wiring connector inside the lamp falls off or is loose.
Check whether the electronic components of lamps (such as electronic transformer, PCB board, motor control board, etc.) are loose, short-circuited and burned out.

When working, the X-axis or Y-axis of the lamp is not normal.
Check one by one according to the previous step;
Check whether the drive belt corresponding to the X and Y axis directions in the lamp falls off and breaks;
Check whether the data feedback receiver (optical coupler) corresponding to the X and Y directions in the lamp is damaged;
Reboot and reset once.